Technical Parameters
The table lists typical configurable values for equipment used in FKM molding. Final specifications depend on your compound, mold and volume, and are confirmed in the technical agreement.
| Parameter | Typical Range | Relevance to FKM |
|---|---|---|
| Machine type | Compression press, or injection machine | Injection saves material at higher volume |
| Clamping force | 50 - 500 tons | Set by projected area and injection pressure |
| Platen size | About 400 x 400 mm to 900 x 900 mm | Fits single and multi-cavity molds |
| Platen temperature | Up to about 200 degrees C, higher on request | FKM often cures at around 170 to 190 degrees C |
| Temperature uniformity | About plus or minus 2 degrees C | Even cure and consistent properties |
| Pressure control | Programmable with automatic make-up | Keeps the mold closed through the cure |
| Vacuum option | Chamber type, about -0.095 MPa and below | Fewer bubbles and flow marks |
| Shot control (injection) | Closed-loop with cushion monitoring | Less waste on an expensive compound |
| Control | PLC with touchscreen and recipe memory | One recipe per compound and mold |
How to read the table: for FKM, the most important numbers are temperature uniformity and parallel closing. Uneven heat gives parts that cure differently across a multi-cavity mold, and a press that closes out of parallel creates flash, which in FKM means wasted money.
The second key point is the choice between compression and injection. Compression is flexible and has a lower machine cost, but it uses a preform for each cavity and produces flash. Injection with a cold runner mold reduces material waste, and at high volume the saving on FKM can be large. Please send your part drawing, compound, annual volume and mold dimensions, and we will compare both routes with you.
Practical advice. Ask your compound supplier for the recommended cure temperature and the post-cure schedule, and send them with your inquiry. It helps us choose the right platen range and heating design.
Special Focus: Mold Fouling, Shrinkage, Post-Cure and Material Cost
FKM buyers usually have specific problems in mind. The table links the main ones to what helps in the machine and the process.
| Problem | Likely Cause | What Helps |
|---|---|---|
| Mold fouling and sticking | Compound residue and fluorine-containing deposits on the cavity | Regular mold cleaning, suitable release practice, even temperature |
| High scrap cost | Overweight preforms, large flash, runners | Accurate preforms, parallel closing, cold runner injection |
| Bubbles and voids | Trapped air or moisture | Breathing steps, vacuum option, dry material |
| Property variation | Uneven temperature or short post-cure | Zoned heating, planned post-cure |
| Dimension variation | High mold shrinkage, uneven cure | Stable temperature, shrinkage allowance in the mold |
| Poor bond to metal | Weak surface preparation or bonding agent | Clean inserts, correct adhesive, stable heat and pressure |
Points that decide success:
- Post-cure. FKM parts are normally post-cured in an oven, often at around 200 to 230 degrees C for several hours, to complete the cure and reduce volatile residues. This is a separate process and equipment, and the schedule must follow your compound data sheet.
- Mold care. Fouling builds gradually, so cleaning on a schedule keeps surface quality and dimensions stable. Mold surface treatments can help, and your mold maker can advise.
- Shrinkage. FKM shrinks more than many other rubbers, so the mold design must allow for it. We cannot change this in the press, but we can keep temperature steady so shrinkage stays predictable.
- Material cost. A small saving per part on FKM adds up quickly. Compare compression and injection on total cost, including scrap, trimming and labor.
For bonded FKM parts, our rubber-to-metal bonding machine page describes that process in more detail. Compound choice and bonding agents belong to your suppliers, and the machine provides a stable, repeatable curing condition.
Honest advice. For low volumes and many sizes, a good compression press with accurate preforms is usually the best value. Injection pays off when volume is high and the part is stable.
Automation and Control System
An expensive compound needs a control system that repeats every cycle exactly and warns early when something drifts.
- Recipe memory: temperature, pressure steps, breathing steps, vacuum and cure time are stored for each compound and mold.
- PID temperature control: separate heating zones keep the platen even at higher settings and limit overshoot.
- Breathing function: programmable open-and-close steps release gas and moisture early in the cure.
- Automatic cure timer and auto-open: the press opens at the end of the cure, so parts are not over-cured when the operator is busy.
- Closed-loop shot control (injection): position-based shot measurement and cushion monitoring reduce scrap and flash.
- Alarm display and counters: faults are shown clearly, and cycle counters record output.
Handling: FKM molds are often used hot and cleaned often. Slide-out tables, mold carts and loading frames make mold changes and cleaning safer and faster. For higher volumes, an automatic mold loading and unloading system or a robot can be added in stages.
Preform control. Because compound cost is high, weighing preforms before loading is a simple, effective habit. A scale at the press, linked to your recipe sheet, helps operators stay within the weight limits.
Operator view. The touchscreen shows the active recipe, platen temperatures and cure time remaining. Passwords protect settings. An English manual and training material are provided, and remote support is available when your technician sets up a new mold.
Changeover tip. Name each recipe after the mold number and compound code, so any operator can recall the right settings quickly. Keep a printed sheet of proven settings near the press, so that new staff start from tested values, and lock the recipes by password to prevent accidental changes between shifts.
Structure and Materials
FKM molding runs at high temperatures and demands precise closing, so the structure of the machine must stay stable in constant heat.
| Component | Design and Material | Purpose |
|---|---|---|
| Frame | Welded steel, stress relieved | Rigid base for parallel closing |
| Platens | Alloy steel, ground flat, zoned heating | Even heat and flat contact with the mold |
| Heating | Electric rods or oil channels, with PID control | Reach and hold higher temperatures |
| Insulation | Boards and shields on platens and guides | Lower heat loss, protection for seals and sensors |
| Guide system | Wear-resistant guides, adjustable | Keeps platens parallel and flash low |
| Cylinders and hydraulics | Quality seals, filtered and cooled oil | Stable pressure and long seal life |
| Injection unit (if used) | Hardened screw, barrel and plunger | Accurate shots with abrasive fluoroelastomer compounds |
Heat management: at higher platen temperatures, heat moves into guides, cylinders and sensors. We use insulation, heat shields and cooling where needed, so seals and electronics stay in their safe range. Platen edges lose heat faster than the center, so extra heating power or insulation at the edges helps keep temperature even.
Corrosion note: FKM can release small amounts of acidic vapors at high temperature, especially during post-cure. Keep these vapors away from steel parts and electronics through good ventilation, and use protective coatings where needed.
Maintenance. Clean platens regularly with non-scratching tools, keep guides lubricated, check cylinder seals and change hydraulic oil and filters according to the manual. For injection machines, inspect screw, barrel and plunger wear at planned intervals.
Before shipment, each machine is run under load with a test mold, and temperature uniformity, pressure holding and safety functions are checked.
Safety and Energy Efficiency
FKM molding combines high temperature, high pressure and potentially irritating vapors, so careful safety design and good ventilation are essential.
- Emergency stop at the operator position and at the loading side
- Light curtain or guard doors connected to the PLC
- Hydraulic overpressure protection with a relief valve and pressure monitoring
- Independent over-temperature protection on each heating zone
- Insulated surfaces and warning labels on hot parts
- Vacuum chamber interlock on vacuum models, so the chamber cannot open until pressure equalizes
Handling advice: fluoroelastomers must not be heated far above their recommended processing temperatures, since decomposition can release harmful fumes. Never exceed the temperatures in the compound data sheet, never smoke near FKM scrap, and provide local exhaust above the press, the mold area and the post-cure oven. Wear heat-resistant gloves and sleeves, and use lifting aids for heavy molds. Follow the safety data sheets from your material supplier.
Energy efficiency: good insulation and PID control lower the power needed to reach and hold higher temperatures. A variable-speed hydraulic system uses power mainly while the machine moves, and a stand-by temperature function saves energy during breaks. The largest saving on FKM is usually material, so accurate preforms, low flash and cold runner molds matter as much as electricity.
Tell us your working hours and local power price, and we will compare options in the quotation.
Training and records. Keep a log of safety checks, ventilation checks and oil changes. A monthly test of the emergency stop, light curtain and over-temperature cut-off keeps the machine dependable.
Fume and housekeeping. Keep the floor around the machine tidy, collect flash and trimmings in a bin and remove them regularly. Store release agents and cleaning solvents in labeled containers away from hot surfaces, and follow the supplier's safety data sheets. A clean, well-ventilated workshop lowers the risk of slips, burns and unpleasant odors during long shifts.