Technical Parameters
The table below lists typical configurable ranges for a vacuum degassing vulcanizing machine. Delidong builds each unit to the customer's mold size, tonnage and product, so final figures are confirmed in the written quotation and the technical agreement before production starts.
| Parameter | Typical Range | Notes |
|---|---|---|
| Clamping force | 100 - 1000 tons | Selected from projected area of the part and cavity pressure |
| Heating platen size | 400 x 400 mm up to 1000 x 1000 mm and larger | Custom sizes available for large molds |
| Platen temperature | Up to 200 degrees C standard | Higher range available on request |
| Temperature uniformity | About plus or minus 2 degrees C | Depends on platen size and zone layout |
| Vacuum level | About -0.095 to -0.1 MPa (gauge) | Depends on pump selection and chamber volume |
| Vacuum chamber | Sealed enclosure around mold and platens | Door or lift-up design, chosen by mold handling method |
| Daylights | 1 to 6 layers | More layers raise output per press |
| Control system | PLC with touchscreen | Recipe storage, alarms and data records |
| Pressure holding | Programmable, with automatic make-up | Keeps pressure stable during the cure |
How to read these figures: clamping force should be sized so that cavity pressure stays under the press rating with a safety margin. Vacuum level matters less than pump-down time, because a chamber that reaches vacuum slowly adds seconds to every cycle. Send us your mold drawing and compound type and we will recommend a chamber volume and pump size that fit your target cycle time.
How to Select the Right Size
Selection normally follows four steps:
- Calculate the projected area of all cavities and multiply by the cavity pressure of your compound to find the required clamping force.
- Add a safety margin of about 15 to 25 percent, so the press does not run at its limit every cycle.
- Check platen size and daylight against the mold, including the space needed for loading and inserts.
- Review output: if one layer is not enough, a multi-layer press raises output without more floor space.
Our engineers can complete this calculation for you from a drawing.
Key Considerations for Vacuum Vulcanizing
Buyers who compare vacuum degassing machines usually find that the spec sheets look similar, while real performance differs. These are the points experienced rubber molders focus on:
- Chamber sealing and pump-down speed. Seal material, door geometry and chamber volume decide how fast the vacuum is reached. A smaller chamber built tightly around the mold is usually faster than a large generic box.
- Compound outgassing. Some compounds release moisture or plasticizer vapor under vacuum. The pump, trap and oil change interval must match, otherwise pump oil degrades quickly and the vacuum level drifts.
- Timing of vacuum and pressure. Pulling vacuum too late traps air, and applying full tonnage too early can seal the mold edge before degassing is finished. Our PLC lets you set the vacuum hold and the pressing point separately.
- Mold design. Parting lines and vent grooves should work with the vacuum, not against it. We can review your mold drawing before you order.
- Heat-up and recovery. After each mold change the platens should recover temperature quickly, or the first parts of every batch become scrap.
A practical comparison: conventional press with manual bumping is cheaper to buy, but quality depends on the operator. Vacuum degassing press costs more up front, yet gives repeatable results and a lower reject rate. For high-value parts, the payback is often measured in months, not years.
Common Buying Mistakes
After many projects, we see the same mistakes repeated:
- Choosing by tonnage alone. Two presses with the same tonnage can behave very differently if platen flatness and temperature control differ.
- Ignoring mold maintenance. A worn mold wastes the benefit of a good press.
- Buying too large. Oversized equipment costs more to run and heat.
- Skipping spare parts. Wear items such as the vacuum pump oil, chamber seals and vacuum sensor are cheap to stock and expensive to wait for.
Avoiding these four points saves more money than most negotiations on price.
Automation and Control System
The control system of a vacuum degassing vulcanizing machine has to coordinate three things at once: mold closing, vacuum timing and heating. Delidong machines use a PLC with a color touchscreen, so operators can set and review the full cycle without special training.
- Programmable cycle steps: mold close, pump-down, vacuum hold, pressing, pressure holding, vacuum release and mold open can each be timed separately.
- Recipe storage: parameters for different molds and compounds are saved, so a product change takes a few touches instead of a manual set-up.
- Multi-zone temperature control: each heating platen is controlled by its own sensor and output for stable temperature across the plate.
- Alarms and interlocks: low vacuum, over-temperature, oil level and pressure faults are shown on screen and stop the cycle safely.
- Optional data records: cure time, temperature and vacuum value can be logged for customers who need traceability.
For higher output, the press can be combined with automatic mold loading and unloading or a mold shuttle system. In that case the vacuum chamber door, mold carrier and PLC are designed as one unit, so the cycle stays synchronized. If you plan to automate later, tell us now, and we will leave the right space and interfaces in the electrical design.
Operator Experience and Training
Even a well-designed system must be easy to run on the shop floor. The touchscreen uses clear step names and plain parameter fields, so a new operator can load a stored recipe, check the cure status and handle common alarms after a short training session. We provide an English manual and, when needed, a short video guide for daily operation. Supervisors can lock critical parameters with a password, so that settings which affect how fast the vacuum is reached and how stable it stays during the cure are not changed by accident. Remote support is available if your engineer wants a second opinion on a recipe.
Structure and Materials
Stable molding results start with a rigid machine. A vacuum degassing vulcanizing machine carries high clamping force and a heated, sealed chamber at the same time, so frame stiffness and sealing quality both matter.
| Component | Design and Material | Why It Matters |
|---|---|---|
| Press frame | Welded steel plate frame, stress relieved | Resists deflection under full tonnage |
| Heating platens | High-grade alloy steel, precision machined | Even heat and flat mold surfaces |
| Heating elements | Electric heating rods or other heating media on request | Fast heat-up and easy maintenance |
| Vacuum chamber | Welded steel enclosure with heat-resistant seals | Holds vacuum through repeated heat cycles |
| Hydraulic cylinder | Honed cylinder with quality seals | Smooth pressure and long service life |
| Insulation | Insulation boards between platens and frame | Cuts heat loss and protects the structure |
Details that extend service life: thermal insulation reduces energy use and keeps the frame cool. Chamber seals are standard wear parts, so we design them for easy replacement and can supply spare sets with the machine. The hydraulic station is separated from the heated area to reduce oil temperature and prolong oil life.
All major steel parts are machined and assembled in our own workshop, and the finished press is tested with load before shipment, so flatness, parallelism and vacuum tightness are checked before the machine leaves the factory.
Maintenance-Friendly Design
A machine that is easy to maintain keeps its accuracy longer. We place service points, such as filters, valves and sensors, where a technician can reach them without removing large parts. Guide surfaces and seals are designed as replaceable items, and the manual lists a suggested inspection routine: daily visual checks, weekly lubrication and cleaning, and a deeper check every few months. Pay special attention to the vacuum pump oil, chamber seals and vacuum sensor, because these items influence how fast the vacuum is reached and how stable it stays during the cure more than any other part of the machine.
Safety and Energy Efficiency
A press that combines high pressure, high temperature and vacuum needs a careful safety design. Delidong machines include the following protections as standard or as options:
- Emergency stop buttons within easy reach on the operator side
- Safety guards or light curtains at the mold loading area, wired into the PLC
- Hydraulic overpressure protection with a pressure relief valve and a monitored pressure sensor
- Over-temperature cut-off for each heating zone, independent of the main control
- Vacuum chamber interlock so the chamber cannot be opened until pressure has equalized
- Insulated surfaces and warning labels on hot areas
Energy efficiency matters because heated platens run all day. Insulation boards reduce heat loss, and PID temperature control avoids overshoot. The hydraulic system can use a variable-speed pump or servo drive, which draws power mainly when the press is moving or building pressure. In typical continuous operation, an energy-saving hydraulic configuration can reduce electricity use noticeably compared with a constant-speed pump, though the saving depends on duty cycle.
If your plant has specific safety rules, send them to us at the quotation stage and we will adapt the guarding and electrical layout.
Daily Safety Habits
Good equipment still needs good habits. We suggest the following routine for every shift:
- Check emergency stop and guard function before starting production
- Wear heat-resistant gloves and avoid reaching between platens
- Never bypass interlocks, even for a quick adjustment
- Report oil leaks or unusual noise immediately
- Lock out power before maintenance work
We include warning labels and a safety section in the English manual.
Ask for a safety walk-through. During commissioning, our engineer or your own technician should test every emergency stop, guard and interlock together, and record the result. For vacuum degassing, also confirm the alarm behavior for temperature and pressure faults, because these are the situations where a quick and predictable stop matters most. A short written checklist from this test is useful for your internal safety file and for new staff training.