Technical Parameters
The table lists typical configurable values for an LSR dosing mixing machine. Final specifications depend on your material, drum size and injection machine, and are confirmed in the technical agreement.
| Parameter | Typical Range | Notes |
|---|---|---|
| Material components | Two-part LSR, A and B | Platinum-cured grades are the most common |
| Mixing ratio | Usually 1:1, adjustable on request | Set by the material supplier's data sheet |
| Ratio accuracy | Typically within about 1 percent | Depends on pump type, material and calibration |
| Supply container | 20 liter pails or 200 liter drums | Follower plate pumps empty the container evenly |
| Pump type | Piston pumps, driven by air or servo | Gives smooth, repeatable flow |
| Color dosing | Third channel, often about 0.5 to 3 percent | Pigment paste is added before the mixer |
| Mixer | Static mixer with replaceable elements | Blends without a moving part in the material |
| Output flow | Adjustable to match the injection unit | Sized to the shot volume and cycle |
| Control | PLC with touchscreen, linked to the injection machine | Starts and stops with the machine cycle |
How to read the table: the most important points are ratio accuracy, pump type and the way the container is emptied. Piston pumps with good seals give steady flow, and a follower plate that presses on top of the material pushes it out without trapping air.
The second key point is the output flow compared with your shot size and cycle. A unit that is too small cannot refill between shots, while a very large one wastes material during flushing. Please send your part weight, cavity number, cycle time and material, and we will recommend the pump size and options.
Practical advice. Ask for the material supplier's data sheet at the quotation stage. The viscosity of the LSR affects pump size and hose diameter, and different brands can behave very differently in the same unit.
Special Focus: Ratio, Bubbles, Color and Cleanliness
Buyers of LSR feeding systems usually care about four things, and the table links each one to what the dosing machine should provide.
| Concern | What Goes Wrong | What the Dosing Machine Should Provide |
|---|---|---|
| Mixing ratio | Soft, sticky or brittle parts | Accurate pumps, calibration function and ratio alarm |
| Air in the material | Bubbles, voids, surface defects | Air-free container change, bleed valves and sealed lines |
| Color consistency | Streaks or shade changes between shots | Steady pigment dosing and good static mixing |
| Material change | Cross-contamination and long downtime | Easy flushing, quick-release hoses and mixers |
| Cold line temperature | Material curing in the lines | Cooled supply and cooled nozzle zone |
Practical details that save trouble:
- Keep the material cool. LSR starts to cure with heat, so lines and the nozzle area are kept cool until the material enters the hot mold.
- Avoid contamination. Platinum-cured silicone can be poisoned by sulfur, some amines, tin compounds and certain gloves or rubbers. Keep these away from the material, the lines and the mold.
- Change the mixer element on schedule. A partly clogged mixer changes pressure and ratio quality over time.
- Calibrate regularly. Run a simple weight check on each component from time to time, and record the result.
The dosing unit works with the injection machine and the mold, and each part has to be right. A good dosing system cannot fix a leaking mold, and a good mold cannot fix a wrong ratio. We will review the whole system with you and say plainly where the limits are.
Pigment note. Pigment pastes should be compatible with the silicone grade, especially for food or medical products. Ask your silicone supplier for approved colorants.
Automation and Control System
The control system of an LSR dosing mixing machine has to deliver material exactly when the injection machine asks for it, in exactly the right ratio.
- Synchronization with the injection machine: the dosing unit refills the injection unit during the cure, without waiting at the end of the cycle.
- Ratio monitoring: flow or pump stroke sensors compare both components, and an alarm warns the operator when the ratio moves out of limits.
- Container level and change-over: sensors show when a pail or drum is nearly empty, and a controlled change sequence reduces air in the lines.
- Pressure monitoring: a pressure sensor in the line detects blockages and worn mixers early.
- Color control: the pigment pump follows the main flow, so the color percentage stays constant when the speed changes.
- Recipe storage: ratio, flow and color settings are saved for each material and part.
Cleaning and flushing sequence: a guided routine on the screen helps operators flush lines, change mixers and restart without mistakes.
The unit can be connected to a factory network for data export, and our engineers can support remote diagnosis if you permit it. If you plan to feed several injection machines from one dosing unit, tell us early, since the control and the hose layout change.
Operator view. The touchscreen shows the active recipe, container levels, ratio, pressure and alarms in plain language. Passwords protect settings, and an English manual and training material are provided.
Changeover tip. Name each recipe after the silicone brand, grade and part code, so any operator can recall the right settings quickly. Keep a printed sheet near the unit with the ratio, flow and flushing steps, and lock recipes by password to prevent accidental changes between shifts.
Structure and Materials
LSR is a clean, precise material, and the dosing machine must be built to keep it that way. Materials in contact with the silicone, and the way the unit is built, make a clear difference to its life and its cleanliness.
| Component | Design and Material | Purpose |
|---|---|---|
| Frame | Welded steel or stainless steel, with casters or fixed base | Stable and easy to clean |
| Pumps | Hardened and polished pistons, quality seals | Steady, repeatable flow |
| Follower plates | Aluminum or stainless, with seals for the container wall | Empty pails or drums without trapped air |
| Hoses and fittings | Material-compatible tubing with quick-release couplings | Pressure resistance and fast changeover |
| Static mixer | Replaceable elements in a stainless housing | Reliable blending without moving parts |
| Cooling circuit | Water or chiller loop for lines and nozzle area | Keeps material from curing early |
| Control cabinet | Sealed, separate from material area | Protects electronics from dust and spills |
Detail that matters: pump seals are the part that wears first, because LSR can contain fillers that are slightly abrasive. We select seal materials to match the silicone and make them easy to replace, with spare sets supplied.
For medical, food-related or baby products, we can discuss stainless contact surfaces, smooth internal finishes and lubricants that suit your needs. Please share your requirements at the inquiry stage, since it changes the material choice.
Maintenance. Replace the static mixer on a planned schedule, check seals and hoses for leaks, keep the area around the pumps clean and calibrate ratio regularly. Use only the cleaning agents recommended by your silicone supplier.
Before shipment, each unit is run with a test material or a suitable fluid, and ratio, flow and alarm functions are checked.
Safety and Energy Efficiency
An LSR dosing unit works with pressurized lines, compressed air or servo drives and sometimes with chemical materials, so safety needs the same care as any production machine.
- Pressure relief valves and pressure sensors on pump and mixer lines
- Emergency stop within reach of the operator
- Guards and interlocks on moving pumps and follower plates
- Safe container change-over with pressure release before opening
- Drip trays and spill control under pumps and fittings
- Clear warning labels for pressure, moving parts and material handling
Handling advice: follow the silicone supplier's safety data sheets, wear gloves and eye protection that is compatible with the material, and keep components in labeled containers away from heat sources. Release pressure before opening any line, and never reach into the follower plate area when the pump is active.
Energy and material efficiency: a servo-driven pump uses power only when it moves, and a sealed, cooled system needs little energy beyond the chiller. The greater saving is material. A good dosing unit and a cold runner mold reduce waste, shorten flushing and avoid scrap from wrong ratio, and LSR is a costly material.
Tell us your working hours and your drum size, and we will compare options in the quotation.
Training and records. Keep a log of ratio checks, mixer changes and seal replacements. A short monthly safety test of the emergency stop, interlocks and pressure relief function keeps the unit dependable.
Housekeeping. Keep a tray under the pumps and fittings, wipe spills at once with the cleaning agent your silicone supplier recommends and dispose of waste material according to local rules. Cured silicone offcuts are usually easy to remove, but uncured material on floors is slippery, so mark and clean such areas quickly.